Refine Your Search

Topic

Search Results

Standard

TEST PROCEDURE FOR ELECTRICAL GROUND ATTACHMENTS

2022-02-25
HISTORICAL
USCAR26
This test procedure is intended to evaluate and/or validate electrical ground schemes for use on the body or chassis. There are two classes based on the expected environmental conditions. Exposed Grounds can be located anywhere in the vehicle (except on the powertrain) and is the class for which most schemes should be tested. Unexposed Grounds can only be used in the passenger compartment or trunk and as such are special cases. This procedure as written is not intended for testing powertrain grounds where high temperatures and vibration levels may be encountered. These situations may require modifications to this procedure and are left to the Responsible Engineer to determine. This specification does not specifically address validation of terminal to wire electrical crimps. Crimps are tested to SAE/USCAR-21
Standard

USCAR-17 SUPPLEMENT

2016-07-21
HISTORICAL
USCAR18-4
This document is a supplement to SAE/USCAR 17 and is intended to give recommended usages for one and two-way RF connectors and dimensional requirements for 2-way RF connectors and hybrid (RF & DC power) connectors which are not currently specified elsewhere. The radio frequency (RF) connector interface specified herein is suited for unsealed and sealed automobile applications up to 6 GHz and is intended for in-line, board mount, device mount, straight or angled applications. Dimensional requirements are specified in this document to ensure interchangeability. Compliance with the dimensional requirements of this specification will not guarantee interoperability between different suppliers mating connectors. It is the supplier responsibility to ensure RF performance requirements are met with other suppliers mating connectors. Performance requirements are specified in SAE/USCAR-2, and in SAE/USCAR-17.
Standard

WIRING COMPONENT DESIGN GUIDELINES

2001-12-01
HISTORICAL
USCAR12-2
This document gives general guidelines to be used during the connector design stage. Various guidelines may not apply in all situations. Therefore, sound engineering judgment must be used in their application. Consider these guidelines as the basis for connector and wiring DFMEA’s. Items in this document are grouped by DFMEA functional requirements. Groups are as follows: A Non-functional Drawing Requirements B Electrical Continuity C Electrical Isolation/Sealing D Device Assembly E Harness Assembly F Vehicle Assembly G Serviceability
Standard

WIRING COMPONENT DESIGN GUIDELINES

1999-07-01
HISTORICAL
USCAR12
This document gives general guidelines to be used during the connector design stage. Various guidelines may not apply in all situations. Therefore, sound engineering judgment must be used in their application. Consider these guidelines as the basis for connector and wiring DFMEA’s. Items in this document are grouped by DFMEA functional requirements. Groups are as follows: A Non-functional Drawing Requirements B Electrical Continuity C Electrical Isolation/Sealing D Device Assembly E Harness Assembly F Vehicle Assembly G Serviceability
Standard

WIRING COMPONENT DESIGN GUIDELINES

2009-07-10
HISTORICAL
USCAR12-3
This document gives general guidelines to be used during the connector design stage. Various guidelines may not apply in all situations. Therefore, sound engineering judgment must be used in their application. Consider these guidelines as the basis for connector and wiring DFMEA’s. Items in this document are grouped by DFMEA functional requirements. Groups are as follows: A Electrical Continuity B Electrical Isolation/Sealing C Device Assembly D Harness Assembly E Vehicle Assembly F Materials G Serviceability H Environmental Requirements I High Voltage (≥ 60V) Application Requirements
X